If a house has radiators, it has a boiler, and a boiler is not something a standard home inspection can fully judge. Virginia’s home inspector rules require the inspector to look at the heating equipment, its controls, the energy source, the distribution system and the flues, but they exclude heat exchangers and let the contract exclude efficiency and adequacy. So you learn what is visible and what is obviously wrong. You still need to ask about age, service and what has been replaced.
This guide is for buyers looking at older homes in the City of Richmond and nearby, where radiators and baseboard heat show up in listing photos. For forced air systems, see our post on HVAC age and inspection negotiation. For fuel questions (tanks, shutoffs, which fuel feeds the boiler), see gas, propane and heating oil.
Recognizing steam and hot-water systems
Start in the basement or utility room. A boiler with a glass tube showing a water line, called a gauge glass, points to steam. A U.S. Department of Energy Building America guide on steam systems for multifamily buildings lists the gauge glass, a pressure control called a pressuretrol, a low-water cutoff, main-line air vents and radiator vents as the parts to find. It says one-pipe steam systems were common in buildings built between 1900 and 1930. In those systems steam rises to the radiators and the condensed water drains back down the same pipe.
That guide is aimed at multifamily buildings, so treat it as a recognition aid, not a home checklist. Upstairs, look at the radiators. A small vent near the top of a radiator, and a single pipe feeding it, matches the one-pipe design the guide describes. If you cannot tell whether the system is steam or hot water, ask the seller and ask your inspector to name it in the report. The federal energy page on residential gas boilers lists hot-water output for residential units, so hot water is the other system you may meet.
What the inspector will and will not do
Virginia’s home inspector regulation, 18VAC15-40-130, sets the minimum report content. This is what the Virginia regulation text says about heating:
| Item | What the rule says |
|---|---|
| Inspected and described (C.7) | Heating equipment and its operating controls, energy source, heating distribution system, vent systems, flues and chimneys including dampers |
| Scope | Readily accessible components and readily observable defects, unless the contract limits it |
| Excluded from the equipment item | Heat exchangers, gas logs, built-in gas appliances, stoves, space heaters, solar heating, humidifiers and air purifiers |
| Cannot be inspected | The report must identify the component and explain why (section D) |
| System shut off or winterized | The inspector need not bring it into operation, and the report must state why it was not inspected (section E) |
| Contract exclusions (18VAC15-40-120 B.7) | Strength, adequacy, effectiveness or efficiency of any system, causes of conditions and costs of correction |
The regulation text does not name radiators or boilers. Whether a given inspector treats them under the equipment or distribution item is a question for that inspector. Ask which one, and ask for the report to say what was and was not tested.
Searching for older homes? Tell us where.
Send us the areas you are considering and we will set up a saved search. When a listing mentions a boiler or radiators, the questions in this guide are the ones to bring to the showing.
Age, service and replacement: what to ask the seller
The federal page on residential gas boilers does not state a boiler lifespan. It says good maintenance extends the useful life of a boiler and improves efficiency. That makes the data plate and the service history the facts that matter.
- When was the boiler installed, and what does the data plate show?
- Who services it, and are there invoices for the last few years?
- Has the burner, a vent or the low-water cutoff been replaced?
- Does any radiator stay cold, bang or leak at a valve?
- What fuel does it burn, and where are the shutoff and the tank, if any?
- Is any pipe wrap suspected to contain asbestos?
Ask for answers in writing and use them with the inspection report. Cost questions are worth a quote from a licensed heating contractor on the actual house.
Efficiency on paper
The federal energy page uses an example of a gas boiler to show how efficiency affects fuel use. Under its assumptions, a 0.84 AFUE boiler uses 877 therms a year, a 0.90 AFUE boiler uses 790 therms, and a 0.97 AFUE boiler uses 739 therms. AFUE is the share of the fuel that becomes heat. Those are example figures from the page’s own assumptions, not measurements of any Richmond house, and the page covers gas hot-water boilers, not residential steam. Use them for one idea: a higher AFUE number means less fuel for the same heat.
The fuel behind the boiler
A boiler is only as useful as its fuel supply. The Virginia rule above puts the energy source in the inspector’s report, so the report should say whether the boiler burns gas or oil. If it is oil, ask where the tank is, how old it is and whether any tank is buried. If it is gas, ask whether the gas comes from the street or from a propane tank, and who owns the tank. Our post on fuel sources, tanks and shutoffs goes into those questions, so this guide does not repeat them.
What routine care looks like
The DOE steam guide lists maintenance a homeowner or contractor should keep up. Test the low-water cutoff regularly, draining only until the boiler shuts off, because fresh water adds corrosion. Check for leaks in the return lines by watching how much makeup water the boiler takes. Keep the pressuretrol in the half to one and a half psig range. Test the radiator vents and clean or replace any that do not pass air. Insulate basement steam lines. Those items are a useful template. Ask the seller which of them have been done and when, and ask a heating contractor which apply to the system you are buying. Because the guide is written for apartment buildings, the contractor’s view of a single-family boiler is the one to trust.
Where to look while you tour
Whether you are looking in The Fan, Church Hill, North Side or the Near West End, the checks are the same. Note which rooms have radiators and which do not, and whether any room depends on a portable heater. Look at the pipes in the basement and note any that are wrapped, bare or leaking. Our buyer process page shows when to book the inspection, and our preferred lenders page is a place to start if you want to size a possible replacement into your budget.
Searching for older homes? Tell us where.
Send us the areas you are considering and we will set up a saved search. When a listing mentions a boiler or radiators, bring the questions in this guide to the showing.
Frequently asked questions
What pressure should a one-pipe steam boiler run at?
The Building America steam guide says one-pipe steam systems should typically operate at 1/2 to 1 1/2 psig. A wrong setting can cause short cycling and uneven heat.
Why is one radiator cold?
The same guide lists blocked or painted-over radiator vents and uneven steam arrival times among the causes of uneven heating, and says temperature differences can reach 15 degrees F in an apartment. A heating contractor should check the vents.
Why do the pipes bang?
The guide describes water hammer: condensate carried by fast steam slams into the end of a line. It can crush the float inside a vent. It is worth asking about during a showing.
Should radiator valves be partly open?
The guide says radiator valves should always be fully open or fully closed.
What if the heat is off during the inspection?
Under 18VAC15-40-130 E, a system that is shut off or winterized does not have to be brought into operation, and the report must state why it was not inspected. Ask for a re-check once it is on.
Does it matter if the pipes are bare?
The guide says uninsulated steam pipes lose about five times the heat of insulated pipes. It also says to treat asbestos on pipes as a hazard and consult an abatement professional before any work.
Can the inspector check the heat exchanger?
Not under the Virginia heating item, which excludes heat exchangers. A heating contractor can be hired for a closer look.
Does a boiler need yearly service?
The federal energy page says good maintenance practices extend the useful life of a boiler and improve efficiency but gives no schedule. Ask the seller for service records and your contractor for a schedule.